Universal AI/DI Modbus
Module DMB 96500
- High performance measuring input for all industrial sensors:
Pt, Ni, TC, KTY, mA, V, mV, Ω, Pot, Hz, PWM - Uni-/Bipolar and TRMS capture of current and voltage
- Easy configurable by DIP switch or USB interface
- 15 programmable user-specific settings, directly selectable via DIP switches
- Freely scalable up to 247 DRAGO devices in one Modbus segment
- Protective Separation up to 300 V AC/DC, test voltage 3 kV
- Highest accuracy, measuring resolution up to 24 bit
- Fast measured value processing, high data rate
- In-Rail-Bus Connector for Modbus and power supply
- Extremly slim, only 6.2 mm installation width
- Made in Germany, 5 Years Warranty
|
|
DMB96500
초슬림형 범용 AI / DI 모드버스 RS485 통신 모듈
Universal
AI/DI Modbus Module
DMB 96500
다양한
형식의 신호 측정 입력 Modbus RTU RS485
통신
입력 |
표준신호: 0~20mA
4~20mA 0~10V
2~10V 0~5V
1~5V 2선식
트랜스미터 전원 공급 및 신호
입력 (0~20mA
/ 4~20mA) 전류: 0~1mA
0~20mA 0~100mA
±1mA
±20mA
±100mA 전압: 0~1V
0~10V 0~100V
0~300V ±1V
±10V
±100V
±300V Pt: Pt100
Pt200 Pt500
Pt1000 Pt2000
Pt10000 JPt50
JPt100 Ni: Ni100 Ni120
Ni200 Ni500 Ni1000 열전대(TC): A
B C
D E
J K
L N
R S
T U 션트/mV: 0~50mV
0~100mV 0~500V
±50mV
±100mV
±500mV 저항(R): 0~500Ω
0~5kΩ
0~20kΩ
0~100kΩ 가변저항(전위차계,
Potentiometer): 500Ω
... 100kΩ Frequency:
0~1Hz 0~10Hz 0~100Hz
0~1kHz 0~10kHz
0~200kHz 2진/스위칭: PNP, NPN, SN/Contact, NAMUR, S0-Switch PWM: 0~1Hz
0~10Hz 0~100Hz
0~1kHz 0~10kHz KTY: KTY84-130 등
66개
유형의 센서
|
프로토콜 | Modbus RTU
RS485 |
전원 | 24V DC
(전원
및 통신 배선 Bus 단자 옵션) |
특징 | 다양한
형식의 신호 입력 모드버스
RS485 통신 추가 중계기 없이
최대 247개의 DRAGO 모드버스
모듈 연결 가능 DIP 스위치
또는 PC에서 입력 설정
및 변경 두께
6.2mm 초슬림형
|
- 모든 산업용 센서의 고성능 측정 입력 :
Pt, Ni, TC, KTY, mA, V, mV, Ω, Pot, Hz, PWM
- 전류 및 전압의 단극성/양극성 및 TRMS 캡처
- DIP 스위치 또는 USB 인터페이스로 손쉽게 설정 가능
- DIP 스위치를 통해 직접 선택할 수있는 15개의 프로그램 가능한 사용자별 설정
- 하나의 Modbus 세그먼트에 최대 247개의 DRAGO 장치를 자유롭게 확장 가능
- 최대 300V AC/DC, 시험 전압 3kV의 감전보호
- 24비트까지의 최고 정확도, 측정 해상도
- 빠른 측정값 처리, 높은 데이터 전송률
- Modbus 및 전원 공급용 In-Rail-Bus 커넥터
- 매우 얇은, 단지 6.2mm 설치 너비
- 독일제, 5년 보증
|
모드버스(Modbus)
범용 아날로그/디지털 입력 모듈은 광범위한 산업용 센서와
함께 사용하도록 되어 있습니다. 모든 파라미터는 Modbus
RTU 인터페이스를 통해 설정할 수 있습니다. 일반적으로
가장 많이 쓰이는 입력신호 및 모드버스 출력 모드 조합에
대해서는 DIP 스위치를 통해 설정할 수 있습니다.
변환
결과는 Modbus RTU (RS485) 인터페이스를 통해 읽을 수
있습니다.
2-way
절연은 처리회로와 보조전원 회로에서 센서회로의 신뢰성
있는 분리를 보장합니다. 보조전원 및 Modbus RTU는 연결단자
또는 인레일버스 커넥터(In-Rail-Bus Connector)를 통해 연결할 수 있습니다 (액세서리
참조).
The Modbus Universal AI/DI Module is intended to be used with a wide range of industrial sensors. All parameter can be set via Modbus RTU Interface. A subset of the most common settings is available via DIP switches.
The conversion result can be read over the Modbus RTU (RS485) interface. The 2-way isolation guarantees reliable decoupling of the sensor circuit from the Processing circuit and the auxiliary power circuit. Auxiliary power and Modbus RTU can be connected via the connection terminals or via the In-Rail-Bus connector (see accessories).
Technical Data
Input
Sensor / input signal | Measuring error | TC1) | Pt100 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Pt200 | 0.3 K + 0.05 % m.v. | 0.02 K/°C | Pt500 | 0.2 K + 0.05 % m.v. | 0.02 K/°C | Pt1000 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Pt2000 | 0.2 K + 0.05 % m.v. | 0.02 K/°C | Pt10000 acc. IEC 60751 | 0.2 K + 0.05 % m.v. | 0.06 K/°C | JPt50 (TK3916) acc. JIS C 1604 | 0.2 K + 0.05 % m.v. | 0.03 K/°C | JPt100 (TK3916) acc. JIS C 1604 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Ni100 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Ni120 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Ni200 | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Ni500 | 0.5 K + 0.05 % m.v. | 0.02 K/°C | Ni1000 | 0.25 K + 0.05 % m.v. | 0.02 K/°C | KTY (66 types) | 0.1 K + 0.05 % m.v. | 0.02 K/°C | Measuring rate Pt, Ni, KTY | 4 /s | | Resistor 500 Ω, 5 kΩ, 20 kΩ, 100 kΩ | 0.05 % full scale | 100 ppm/K | Potentiometer 500 Ω, 5 kΩ, 20 kΩ, 100 kΩ | 0.05 % | 100 ppm/K | Measuring rate Widerstand / Pot | 25 /s | | Cable resistance | < 100 Ω, programmable for 2-wire | Connection / Sensor current | 2-, 3-, 4-wire / 0.2 mA, 10 µA | TC sensor type A | 0.5 K + 0.08 % m.v. | 0.1 K/°C | TC sensor type B | 0.5 K + 0.08 % m.v. | 0.15 K/°C | TC sensor type C | 0.5 K + 0.08 % m.v. | 0.1 K/°C | TC sensor type D | 0.5 K + 0.08 % m.v. | 0.1 K/°C | TC sensor type E | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type J | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type K | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type L | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type N | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type R | 0.5 K + 0.08 % m.v. | 0.1 K/°C | TC sensor type S | 0.5 K + 0.08 % m.v. | 0.1 K/°C | TC sensor type T | 0.5 K + 0.08 % m.v. | 0.05 K/°C | TC sensor type U | 0.5 K + 0.08 % m.v. | 0.05 K/°C | Measuring rate | 4 /s | | Cold junction compensation | internal, external Pt100 / Pt1000, programmable, uncompensated | Current ±1 mA, ±20 mA, ±100 mA | 0.05 % full scale | 100 ppm/K | Voltage ±1 V, ±10 V, ±100 V, ±300 V | 0.05 % full scale | 100 ppm/K | mV-Shunt ±50 mV, ±100 mV, ±500 mV | 0.05 % full scale | 100 ppm/K | Measuring rate Current / Voltage | 100 /s | | Input resistance | Voltage: > 100 kΩ, Current: < 55 Ω | Measuring modes | DC, Average, RMS | Additional measuring error in RMS mode (40 Hz to 500 Hz) | 2 % m.v. | | Frequency ≤ 1 Hz (gate time 1000 s) | 0.1 % full scale | 100 ppm/K | Frequency ≤ 10 Hz (gate time 100 s) | 0.1 % full scale | 100 ppm/K | Frequency ≤ 100 Hz (gate time 10 s) | 0.1 % full scale | 100 ppm/K | Frequency ≤ 1 kHz (gate time 1 s) | 0.1 % full scale | 100 ppm/K | Frequency ≤ 10 kHz (gate time 100 ms) | 0.1 % full scale | 100 ppm/K | Frequency ≤ 200 kHz (gate time 10 ms) | 0.1 % full scale | 100 ppm/K | PWM ≤ 1 Hz (gate time 1000 s) | 0.1 % full scale | 100 ppm/K | PWM ≤ 10 Hz (gate time 100 s) | 0.1 % full scale | 100 ppm/K | PWM ≤ 100 Hz (gate time 10 s) | 0.1 % full scale | 100 ppm/K | PWM ≤ 1 kHz (gate time 1 s) | 0.1 % full scale | 100 ppm/K | PWM ≤ 10 kHz (gate time 100 ms) | 0.1 % full scale | 100 ppm/K | PWM measuring range | 1 ... 99 % | | Input signal | NAMUR, SN, NPN, PNP, Push-Pull, S0-Switch type B | Push-Pull voltage level | 3.3 ... 5 V | NPN-Pullup | 3.2 kΩ, always active | PNP-Pulldown | 11 kΩ, always active |
Modbus
Protocol | Modbus RTU (RS485) | Module addressing | 1 to 247 | Response delay | 1 to 1000 ms, programmable | Baud rate | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 | Configuration | Parity: Even, Odd, None | Connectivity | Up to 247 DRAGO Modbus Devices without additional Repeater (1/8 Load) | Indication | Yellow LED on front panel | Measurement range | 0 to 115 % (current and voltage modes) |
General Data
Sampling rate | Up to 100 /s (depending on the applied measurement mode) | Test voltage | 3 kV, 50 Hz, 1 min., Input against Modbus/power supply | Working voltage2) (Basic insulation) | 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 | Protection against dangerous body currents2) | Protective Separation by reinforced insulation acc. to EN 61010-1 up to 300 V AC/DC for overvoltage category II and contamination class 2 between input and output/power supply. | Ambient temperature | Operation: -25 °C to +70 °C (-13 to +158 °F) Transport and storage: -40 °C to +85 °C (-40 to +185 °F) | Power supply | 24 V DC, 16.8 V to 31.2 V DC, approx. 1.3 W | EMC3) | EN 61326-1 | Construction | 6.2 mm (0.244’’) housing, protection type: IP 20, mounting on 35 mm DIN rail acc. to EN 60715 | Connection (captive plus-minus clamp screws) | Solid: 0.5 mm2 - 4 mm2 / AWG 20-12 Fine-stranded: 0.5 mm2 - 2.5 mm2 / AWG 20-14 Stripped length: 6-8 mm / 0.28 in Screw terminal torque 0.8 Nm / 7 lbf in | Weight | Approx. 70 g |
Block
Diagram
|
Dimensions
|
|
|
Terminal assignments
1 | Input RTD / R / Pot / TX+ / Namur+ |
2 | Input RTD / R / Pot / U+ / - |
3 | Input RTD / R / Pot / TX- / I+ / TC+ / mV+ |
4 | Input RTD / R / Pot / U- / I- / TC- / mV- |
|
5 | Modbus A (connected to In-Rail-Bus A) |
6 | Modbus B (connected to In-Rail-Bus B) |
|
7+ | Power supply (connected to In-Rail-Bus D) |
8− | Power supply (connected to In-Rail-Bus C) |
|
Connection Captive plus-minus clamp screws Wire cross-section max. 2.5 mm² / AWG 14 Stripped length 6 to 8 mm / 0.28 in Screw terminal torque 0.8 Nm / 7 lbf in Optional power connection via In-Rail-Bus (see accessories)
|
제품
주문 코드 Order Codes
품목 |
주문번호 |
Modbus 범용 AI/DI 모듈 전원 공급 및 Modbus 연결을
위한 In-Rail-Bus (부속품
참조) 모든 파라미터는 Modbus RTU 프로그래밍
인터페이스를
통해 설정할 수 있습니다. 기본적인 설정은 DIP 스위치를 이용하여
수행할 수도 있습니다.
Modbus Universal AI/DI Module In-Rail-Bus for power supply and Modbus connection |
|
여기에
표기된 사양들은 예고 없이 변경될 수 있습니다! (Specifications