 Modbus
4
Channel 2 AI / 2 AO Module DMB 96400
- Processing
of 4 industrial standard
signals individually configurable
as current or voltage signal
- 4
galvanic isolated I/O ports,
protection against erroneous
measurements due to parasitic
voltages or ground loops
- Protective
5 port separation up to
300 V AC/DC, Test voltage
3 kV
- Fast
signal acquisition, high
measuring rate, short processing
times
- In-Rail-Bus
connector for Modbus and
Power Supply allows fast
and economical installation
- Freely
scalable, up to 247 DRAGO
Module in one Modbus segment
- Extremely
slim design, 6.2 mm slim
housing for a simple and
space saving DIN rail mounting
- Made
in Germany, 5 Years Warranty
|
|
DMB96400
초슬림형 4 채널 2 AI / 2 AO 모드버스
RS485 통신 모듈 4 Channel 2 AI / 2 AO
Module DMB 96400
완전히 절연된 아날로그
I/O 채널 4개, Modbus RTU
입력
(Input
AI) | 전압신호:
0/2 to 10V,
전류신호: 0/4 to 20mA |
출력
(Output AO)
| 전압신호:
0/2 to 10V,
전류신호: 0/4 to 20mA |
프로토콜 |
Modbus
RTU (RS485)
|
전원 | 24V DC |
특징 |
2AI
/ 2AO, 2DI, 4DO 가능 300V
AC/DC까지 5-port 보호 분리,
감전보호 초슬림 하우징, 제품
두께 6.2mm 입력
채널당 매우 낮은 비용
|
- 전류
또는 전압 신호로 개별 설정이 가능한
4개의 산업용 표준신호 처리
- 4개의
갈바닉 절연 I/O 포트, 기생 전압(Stray
Voltage)
또는 접지 루프(Ground
Loop)로
인한 측정 오류로부터 보호
- 최대
300V AC/DC의 5포트 보호 분리, 테스트
전압 3kV
- 빠른
신호 수집, 높은 측정 속도, 짧은 처리
시간
- 모드버스
및 전원공급용 In-Rail-Bus 커넥터로
빠르고 경제적인 설치 가능
- 하나의
모드버스 세그먼트에서 최대 247개의 DRAGO
모듈까지 자유롭게 확장 가능
- 초슬림형 디자인,
간단하고 공간 절약적인 DIN 레일 장착을
위한 두께 6.2mm의 얇은 하우징
- 독일산,
5년 보증
|
DMB96400
초슬림형 4채널 2 AI / 2 AO 모드버스 RS485 통신 모듈
(4 Channel 2 AI / 2 AO Module DMB 96400)은 완전히
절연되고, 독립적으로 설정 가능한 4개의 채널을 제공합니다.
2개의
입력을 전류신호 또는 전압신호 입력으로 설정할 수 있습니다.
또한 디지털 입력(DI) 또는 디지털 출력(DO, 오픈 콜렉터/Open
Collector)으로 설정할 수 있습니다.
2개의
출력을 전류신호 또는 전압신호 출력으로 설정할 수 있습니다.
또한 디지털 출력으로 설정할 수도 있습니다 (활성 로직,
Active Logic 0/10V).
모든
매개변수(Parameter)는 Modbus RTU 인터페이스와 기기의
전면에 있는 프로그래밍 소켓을 통해 설정할 수 있습니다.
무료 PC 설정 소프트웨어는 기기가 작동중에도 확장된
설정과 광범위한 진단 기능을 제공합니다. 일반적으로 많이
사용되는 기능은 DIP 스위치를 통해서도 설정할 수
있습니다.
5포트(5-Port)
절연은 각 채널의 처리 회로 및 전원공급 장치의 안정적인
분리(Decoupling)를 보장합니다. 전원공급과 Modbus RTU는
후면 장착형 In-Rail-Bus 커넥터를 통해 연결됩니다 (부속품
참조).
The
Modbus 4 Channel Analog Module provides four fully isolated,
independently configurable channels.
Two
inputs can be configured as current or voltage inputs.
In addition, these can be configured as digital inputs
or digital outputs (open collector).
Two
outputs can be configured as current or voltage outputs.
In addition, these can be configured as digital outputs
(active logic 0/10 V).
All
parameters can be set via the Modbus RTU interface and
via a programming socket behind the front panel. A free
PC configuration software also offers extended setting
options and extensive diagnostic functions during operation.
A subset of the most common settings is also available
via DIP switches.
The
5 port isolation ensures reliable decoupling of the
channels from each other and from the processing circuit
and the power supply. Power supply and Modbus RTU are
connected via the rearmounted In-Rail-Bus connection
(see Accessories).
| Voltage | Current | Input signal | 0 to 10 V | 0 to 20 mA | Input resistance | ≥ 100 kΩ | ≤ 25 Ω | Overload | ≤ 30 V | ≤ 100 mA | Additional function | DI: 12/24 V (L< 2.0 V H > 8.4 V) DO: Open collector switching output, ≤ 30 V / ≤ 100 mA (drop voltage ca. 2V) |
Output AO
| Voltage | Current | Output signal | 0 to 10 V | 0 to 20 mA | Load | ≤ 5 mA (2 kΩ at 10 V) | ≤ 12 V (600 Ω at 20 mA) | Residual ripple | < 10 mVrms | | Additional function | DO: active switching output 0/10 V |
Protocol | Modbus RTU (RS485) | Module addressing | 1 to 247 | Response delay | 1 to 1000 ms | Baud rate | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 | Configuration | Parity: Even, Odd, None 2 stop bit, None 1 stop bit | Connectivity | Up to 247 DRAGO Modbus devices without additional repeater (1/8 Load) |
Measuring error | < 0.1 % full scale | Temperature coefficient1) | < 100 ppm/K | Resolution | 14 bit | Test voltage | 3 kV AC, 50 Hz, 1 min. All channels against each other and against Modbus/power supply | Working voltage2) (Basic insulation) | 600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 | Protection against dangerous body currents1) | Protective Separation by reinforced insulation acc. to DIN EN 61010-1 up to 300 V AC/DC for overvoltage category II and contamination class 2 between input and Modbus/power supply | Ambient temperature | Operation: -25 °C bis +70 °C (-13 bis +158 °F) Transport and storage: -40 °C to +85 °C (-40 to +185 °F) | Power supply | 24 V DC, voltage range 16.8 V to 31.2 V DC, max. 1.0 W via In-Rail-Bus (see Accessories) | EMC2) | EN 61326-1 | Construction | 6.2 mm (0.244") housing, protection type: IP 20, mounting on 35 mm DIN rail acc. to EN 60715 | Weight | Approx. 70 g |
-
Average TC related to full scale value in specified
operating temperature range, reference temperature 23
°C
- For applications with high working voltages,
ensure there is sufficient spacing or isolation from
neighboring devices and protection against electric
shocks.
- Minor deviations possible during interference
|
Terminal assignments
1 | + U | − I | Input 1 | 2 | − U | + I | Input 1 | | 3 | + U | − I | Input 2 | 4 | − U | + I | Input 2 | | 5 | + U | − I | Output 1 | 6 | − U | + I | Output 1 | | 7 | + U | − I | Output 2 | 8 | − U | + I | Output 2 | | A | | Modbus A | B | | Modbus B | C | − | Power supply | D | + | Power supply |
|
제품
주문 코드 Product line
품목 |
주문번호 |
DMB96400
초슬림형 4 채널 2 AI / 2 AO
모드버스 RS485 통신 모듈 전원공급과
Modbus RTU는 후면 장착형 In-Rail-Bus
커넥터를 통해 연결됩니다 (부속품
참조).
4
Channel 2 AI / 2 AO Module DMB
96400 Power
supply and Modbus RTU are connected
via the rearmounted In-Rail-Bus
connection (see Accessories)
|
|
여기에
표기된 사양들은 예고 없이 변경될 수 있습니다! (Specifications
listed here are subject to change without notice!)
|